C - CAP 03
C-Cap 03 has the same footprint as C-Cap 01 but it has taller element and hence can reach capacitance values up to 29µF
The Coaxial structure of the C-CAP contributes many advantages to among which are:
1. It prevents the magnetic field outside of the capacitor and therefore the induction heating losses are eliminated.
2. Lack of external field prevents the crosstalk with other capacitors and prevent the impact of magnetic field between adjacent components.
3. The coaxial structure creates a homogenous current repartition which prevents hotspots that limit performance of other types of capacitors.
The magnetic field from the busbar is confined between the busbars and the capacitors are mounted outside of the magnetic field. This is in contrast with other capacitor technologies. The bus bar is reduced to its simplest and most effective design.
All C-CAPs are interchangeable, having the same mounting holes and same connections. Custom designs are available upon request.
TYPE | C - CAP 03 | ||||||||||
Dimensions (LxWxH) | mm | 80 x 80 x 82.9 | |||||||||
Weight | kg | 2 | |||||||||
Capacitance (±10%) | μF | 2 | 3.5 | 5 | 7 | 10 | 16 | 29 | |||
Sinusoidal Voltage | Vrms | 900 | 800 | 750 | 700 | 650 | 550 | 500 | |||
Peak Voltage | Vpeak | 1273 | 1131 | 1061 | 990 | 919 | 778 | 707 | |||
Max. Current | Arms | 1000 | 1200 | 1300 | 1400 | 1500 | 1700 | 1900 | |||
Max. Power | kVAr | 800 | |||||||||
Freq Range @ Half Power | kHz | 39-199 | 28-164 | 23-135 | 18.6-111 | 15.1-90 | 13.2-72 | 8.8-73 | |||
Freq Range @ Full Power | kHz | 79-100 | 57-82 | 45-67 | 37-56 | 30-45 | 26-36 | 17.6-25 |